| |
|
|
|
|
|
Trocars
|
Company:
Date:
February 06, 2009
|
|
|
|
|
|
|
|
|
|
The Blunt Tip Trocar consists of a blunt obturator and a valve body/cannula assembly. The valve body/cannula assembly contains an internal flapper valve and seal to prevent gas leakage when instruments are inserted or withdrawn. The Blunt Tip Trocar includes built-in converters to allow insertion of instruments of various diameters. In addition, the device has an external one-way valve for gas insufflation.
|
Company:
Date:
February 06, 2009
|
|
|
|
|
|
|
|
|
|
DEXIDE™ 5 mm Threaded Trocar 2 - 65 mm Sleeves with Woodford Spike™ Trocar and Insufflation Port
|
Company:
Date:
February 06, 2009
|
|
|
|
|
|
|
|
|
|
Trocars
|
Company:
Date:
February 06, 2009
|
|
|
|
|
|
|
|
|
|
Trocars
|
Company:
Date:
February 06, 2009
|
|
|
|
|
|
|
|
|
|
Trocars
|
Company:
Date:
February 06, 2009
|
|
|
|
|
|
|
|
|
|
Trocars
|
Company:
Date:
February 06, 2009
|
|
|
|
|
|
|
|
|
|
The ENDOPATH Dilating Tip Trocar is a full-featured trocar that consists of a flat bladed tip and a spring-loaded blade shield. The shield is designed to cover the flat bladed tip to protect internal structures from puncture or laceration once the abdominal or thoracic cavity has been entered. An integrated stability sleeve option is designed to enhance trocar sleeve fixation in the patient. The integrated trocar sleeve housing contains a sealing system to minimize gas leakage when instruments are inserted or withdrawn, and includes a stopcock valve for gas insufflation.
|
Company:
Date:
February 06, 2009
|
|
|
|
|
|
|
|
|
|
ENDOPATH Large-Port trocars consist of three separate components: an exchange rod, a dilating obturator with threaded conical tip, and a transparent trocar sleeve. The exchange rod is a rigid cylindrical shaft, blunt at both ends, 35cm long. The dilating obturator is tapered and threaded at the tip and designed to dilate an opening created by the 10/11mm or the 12mm ENDOPATH surgical trocar. The trocar sleeve housing contains an external gasket and internal flapper valve with a seal to prevent gas leakage when the exchange rod or instruments are inserted or withdrawn. The trocar sleeve housing
|
Company:
Date:
February 06, 2009
|
|
|
|
|
|
|
|
|
|
The Thoracic Trocar Sleeve consists of a rounded tip obturator which is designed to prevent puncture or laceration to internal structures once the cavity has been entered. The device incorporates stability threads on the sleeve which enhance security as instruments are inserted and withdrawn.
|
Company:
Date:
February 06, 2009
|
|
|
|
|
|