| |
|
|
|
|
|
The AUR™-7 Flexible Ureteroscope is a small diameter, fully deflectable flexible ureteroscope. It permits direct visualization and access to the entire intrarenal collecting system, without dilation in many cases. The large working channel (3.6 Fr) provides simultaneous irrigation and use of a 3 Fr working instrument. The dual deflection provides easier negotiation for tortuous ureters. In addition, the 160° down deflection facilitates viewing of the lower calyx, while the 120° up deflection improves viewing of the upper pole access.
|
Company:
Date:
March 03, 2009
|
|
|
|
|
|
|
|
|
|
The DUR®-8 Durable Flexible Ureteroscope permits direct visualization and access to the entire intrarenal collecting system with little or no dilation.
The DUR®-8 is also ideal for reaching proximal ureteral and renal stones with a 200 micron laser fiber or small lithotripsy probe. The DUR®-8 in combination with the Gyrus ACMI 1.9 Fr or 3 Fr electrohydraulic lithotripsy probe is a cost-effective treatment option for treating stone patients.
|
Company:
Date:
March 23, 2009
|
|
|
|
|
|
|
|
|
|
The Invisio® DUR®-D ureteroscope joins distal sensor Flexible CystoNephroscopes (ICN) and MegaPixel™ Digital Camera systems on the Invisio® Digital Technology Platform, at the forefront of medical visualization technology for total “see & treat” solutions.
|
Company:
Date:
March 03, 2009
|
|
|
|
|
|
|
|
|
|
The URF-P3 features a tip diameter of only 6.9Fr (2.3mm) for minimal invasiveness, an up/down angulation range of 180° for and easy access to previously hard-to-reach areas.
For improved observation, a new optical system has been designed, and a reusable 11.7Fr (3.9mm) sheath dilator, 0.035" guidewire compatible, is also provided to ease insertion.
|
Company:
Date:
March 23, 2009
|
|
|
|
|
|
|
|
|
|
The DUR®-8 Durable Flexible Ureteroscope permits direct visualization and access to the entire intrarenal collecting system with little or no dilation.
|
Company:
Date:
March 03, 2009
|
|
|
|
|
|
|
|
|
|
The DUR®-8 Elite's 8.7 Fr shaft reaches into the body more easily than any comparable scope - providing complete intrarenal access, even reaching the lower pole calyces. It's smooth, lubricious outer covering and working channel ease insertion of both scope and instruments. Its patented torque-stable shaft construction, tight-bend radius tip, and active secondary deflection deliver control at every step of the procedure. It also provides maximum durability - coupling a unique cable compensation system with smooth, powerful active deflection
|
Company:
Date:
March 03, 2009
|
|
|
|
|